4 Purification via Extraction
Purpose
To purify a sample of dibenzalacetone contaminated with bromophenol blue by extracting the bromophenol blue into water.
Expected Learning Outcomes
Purify mixtures through extraction.
Accurately and thoroughly describe the appearance of solids and solutions.
Record experimental procedures and observations in the laboratory notebook such that you can use them in the future the next time you have to perform an extraction.
Introduction
One of the most important physical properties of a substance is its solubility. Whether the substance is soluble in water or not plays a huge role in how it behaves. Most importantly for this lab (and for most of biology) is whether a substance is water soluble (hydrophilic) or fat soluble (hydrophobic/lipophilic). For most (although not all) compounds, the more hydrophilic it is, the less hydrophobic it is and vice versa. This is often reduced down to the phrase “like dissolves like”, meaning that hydrophilic solutes (solute = compound being dissolved) can dissolve in hydrophilic solvents (solvent = liquid used to dissolve solute), but not in hydrophobic solvents. For example, sugar can dissolve in water because they are both hydrophilic, but sugar can’t dissolve in oil because sugar is hydrophilic while oil is hydrophobic. This has profound implications in biology as it helps to explain why lipids form cell membranes. Lipids are made up of a hydrophilic head and hydrophobic tails. When put into water, lipids assemble in such a way that the hydrophilic head points outward so that it can interact with water molecules while the hydrophobic tails point inward so that they only interact with each other.

We are going to take advantage of this tendency of hydrophilic molecules to segregate themselves from hydrophobic molecules to separate bromophenol blue (a hydrophilic molecule) from dibenzalacetone (a hydrophobic molecule). You will learn the details of why bromophenol blue is hydrophilic while dibenzalacetone is hydrophobic next semester and in organic chemistry. For now, just remember that bromophenol blue is hydrophilic and thus soluble in water while dibenzalacetone is hydrophobic and thus soluble in oil. This means that if we add both water and oil to a mixture of bromophenol blue and dibenzalacetone, then the bromophenol blue will end up in the water layer while the dibenzalacetone will end up in the oil layer. We can then separate the two compounds (dibenzalacetone and bromophenol blue) by separating the two layers (oil and water). This is what’s known as a liquid-liquid extraction; a very common technique in both chemistry and biology labs and one that you will use again in organic chemistry.

Instead of using oil (which is messy and difficult to remove from a substance), we will use the hydrophobic solvent ethyl acetate (which is the solvent used in some commercial nail polish removers) so that it can easily be removed by letting it evaporate. To separate the water layer (generally referred to as the aqueous layer) from the ethyl acetate layer (generally referred to as the organic layer because ethyl acetate is an organic solvent for reasons you will learn about in organic chemistry), we use a separatory funnel.

Because water is more dense than ethyl acetate (and more dense than most, but not all organic solvents), the water layer and anything soluble in water (e.g., bromophenol blue) will be at the bottom of the separatory funnel while the ethyl acetate layer and anything soluble in ethyl acetate (e.g., dibenzalacetone) will be above the water layer with a distinct line between the two layers, just like you get when you add oil to water (since oil is also less dense than water). A separatory funnel is specially designed to separate different liquid layers (hence its name) by letting the bottom layer drain when you open the stopcock at the bottom (just like how you let the buret drain last week). Because there is a distinct line between the two layers, you can close the stopcock when that dividing line is in the stopcock and that will give you the water layer in the beaker you drained it into and the ethyl acetate layer in the separatory funnel, thus separating the bromophenol blue and dibenzalacetone that are dissolved in the water and ethyl acetate.

After doing a few processing steps to remove any residual water from the organic layer, you will then evaporate away the ethyl acetate to leave a relatively pure sample of dibenzalacetone that you will purify further next week via recrystallization (another technique commonly used in organic chemistry).
Procedures
You will need to analyze your purified product (dibenzalacetone) for next week’s lab, so do NOT dispose of your product (the organic layer) at the end of the lab. Keep it in your lab drawer.
Purification of Dibenzalacetone via Extraction
Required Special Materials and Chemicals
- starting mixture of 80:20 dibenzalactone:bromophenol blue by mass (1.25 g)
- Sodium sulfate (<2 g)
- saturated sodium chloride solution (brine) (10 mL – use from provided bottle)
- ethyl acetate (25 mL)
Extraction

- Weigh out ~1.25 g of the starting mixture (80% dibenzalacetone by mass) directly into a 100 mL beaker (use a spatula or a scoop to transfer the powder from the stock bottle to the beaker; see your instructor if you’re not sure how to do this properly). Record the mass to the nearest 0.001 g.
- If you weigh out significantly more than 1.25 g, do not put the excess back in the stock bottle! Doing so could contaminate the entire stock bottle, ruining the experiment for every classmate that comes after you. Instead, donate the excess to one of your classmates. If none of your classmates needs extra, you should properly dispose of the extra.
- Record a description of the solid particles in your lab notebook (color, size, shape, variability, flow, etc). Magnifying glasses are provided on the cart to help you with this.
- Setup a 125 mL separatory funnel in a ring stand as shown in the figure above.
- Make sure you have a 250 mL beaker (don’t use a 250 mL Erlenmeyer flask as you will need it for a later step) underneath it in case it leaks when you add any liquid.
- Make sure the bottom of the separatory funnel is below the top of the beaker.
- Check to make sure that there is a black rubber O-ring BETWEEN the nut on the stopcock and the white Teflon washer that presses up against the glass of the separatory funnel (if the O-ring is missing, the separatory funnel will leak, if it is touching the glass of the separatory funnel, it will disintegrate over time).
- Also make sure the nut on the stopcock of the separatory funnel is tight, but not so tight that it is difficult to open and close the stopcock.
- Add 2-3 mL of 1 ethyl acetate to the separatory funnel to make sure it doesn’t leak.
- Make sure the stopcock is closed, meaning the handle of the stopcock should be perpendicular to the axis of the separatory funnel – this means that when the separatory funnel is in the ring stand, if the handle is parallel to the ground, then it is closed.
- Add the stopper to the funnel and invert it to make sure the ethyl acetate doesn’t leak out the top.
- Keep your hand on the stopper to prevent it from falling out, then check your glove to make sure no liquid got on it.
- Note that a separatory funnel should only be capped when you are inverting it. When it is just sitting in the ring stand, the stopper should NOT be in funnel. This is because it is possible for gas to build up in a separatory funnel, which will increase the pressure inside the funnel if the stopper is in it. This could cause the stopper to get blown off the separatory funnel and fall to the ground and break.
- Dissolve the starting mixture that you measured out earlier in ~25 mL of ethyl acetate (use a 50 mL graduated cylinder to measure the volume) by adding the ethyl acetate to the beaker and swirling gently until all the solid disappears (dissolves). Observe what the ethyl acetate looks like before, during and after the solid dissolves.
- Pour the solution from the beaker into the separatory funnel.
- Rinse out the beaker with ~2-3 mLs of fresh ethyl acetate and pour this into the separatory funnel.
- Add ~10 mL of distilled water to the separatory funnel (use a 10 mL graduated cylinder to measure the volume).
- Cap the separatory funnel and invert it as demonstrated in class and in this video (watch from 5:44-6:29; you can ignore what she says about acids and bases, that part isn’t relevant to us). Make sure you have your palm/finger over the stopper so that it doesn’t fall out.
- IMMEDIATELY open the stopcock to vent the separatory funnel. To open the stopcock, turn it so that it is parallel to the axis of the funnel. Make sure that the opening is pointed away from other people as a small amount of liquid might spray out.
- Close the stopcock, invert again, and vent again. Keep inverting and venting until you stop hearing a hiss of escaping gases when you open the stopcock, then you can shake the funnel vigorously for 30-60 seconds between venting. Shake and vent multiple times until you are satisfied that the 2 layers have been thoroughly mixed.

To see a larger version of this image, right click on it and select “open image in new tab”. Credit: Dr. Sam Krerowicz, IU East - Place the separatory funnel back in the ring stand (make sure the stopcock is closed), remove the stopper and wait a minute or two until the organic (top) and aqueous (bottom) layers separate (make note of the color of each layer).
- Not only will removing the stopper keep you safer, but if you don’t remove it, no liquid will come out in the next step and it will be much more difficult to remove the stopper so that you can continue.
- If you don’t see any separation of layers, get your instructor for help.
- Open the stopcock and drain the lower layer into a 250 mL beaker (label beaker as “aqueous layer” using a piece of labeling tape). Observe what the aqueous layer looks like.
- Open the stopcock all the way until the line that should be visible between the organic and aqueous layers is ~1 – 0.5 cm from the bottom of the separatory funnel.
- Let the separatory funnel sit for a few minutes to let any water stuck to the sides of the separatory funnel slide down to the bottom.
- Open the stopcock just enough so that liquid starts slowly draining again.
- Do your best to close the stopcock when the separating line between the layers is in the stopcock itself.
- If you accidentally allow some of the organic layer to drain out of the separatory funnel at this point, you will need to add the water layer back to the separatory funnel and repeat steps 13 and 14.
- Add 10 mL of saturated NaCl solution to the separatory funnel.
- The NaCl solution (brine) will help remove residual water that’s dissolved in the organic layer so you need less sodium sulfate in later steps.
- Repeat steps 10-14, shaking for another minute (you can use the same “aqueous layer” beaker you used previously).
- Pour the organic layer that’s still in the separatory funnel out of the top of the separatory funnel into a 250 mL Erlenmeyer flask.
- Do NOT drain the organic layer out of the bottom of the separatory funnel as that part of the funnel is contaminated with a small amount of the aqueous layer that we just so laboriously removed from the organic layer.
- Rinse separatory funnel with ~2-3 mLs of ethyl acetate and add to Erlenmeyer flask.

Credit: Dr. Sam Krerowicz, IU East - Label a 50 mL beaker with your initials, the date, and “dibenzalacetone in ethyl acetate” (use the label tape in your drawer, weigh it after labeling it), then weigh the beaker on the balance.
- Dry the organic layer with solid sodium sulfate (Na2SO4).
- Add a scoopful of sodium sulfate to the organic layer and swirl.
- If all of the sodium sulfate clumps up and largely sticks to the bottom of the flask, add a smaller scoopful of sodium sulfate as many times as needed for the newly added solid to not clump up or stick to the bottom of the flask (you shouldn’t need a whole lot).
- Once the organic layer is fully dry (i.e. once you have added sufficient sodium sulfate), let the sodium sulfate settle to the bottom of the flask for a few minutes, then slowly decant the organic layer into a such that no solid is transferred into the beaker and the solution is completely clear (not cloudy).
- If you are unable to decant the liquid successfully (solution has particulates or is cloudy), gravity filter the liquid into the beaker instead. Instead of using the folding of the filter paper described in the appendix, use fluted filter paper (see here for a demonstration of how to fold filter paper so that it is fluted).
- Store the beaker (do NOT cover it) in your drawer to let the solvent evaporate (make sure it won’t get knocked over when you close your drawer). Once the solvent has evaporated, you will recrystallize the residue next week to further purify it.
Waste
- the aqueous layers may be disposed of down the drain with lots of water
- the Erlenmeyer flask with the sodium sulfate should be set in the fume hood for a few minutes to let the residual ethyl acetate evaporate and then the sodium sulfate should be scraped out into the solid inorganic waste baggy at the front of the room. Any sodium sulfate that can’t be scraped out may be rinsed down the drain with lots of water
- any starting mixture that was spilled may be disposed of in the normal trash as neither bromophenol blue nor dibenzalacetone are hazardous materials
- all glassware used should be washed with soap and tap water and then rinsed thoroughly with distilled water before being placed back in your lab drawer (if that’s where you got it from) or into the dirty dish bin at the front of the lab (if you got it anywhere other than your drawer)